PLC Programmable Logic Controller ELC-12DC Ethernet 12-24VDC 8 inputs, 4 Outputs
PLC Programmable logic controller for 12/24VDC Rievtech Product List: 1 PLC Controller1 USB Programming interface cable 1 24VDC DIN Power Supply 1 DIN Rail 8 inc 1 USB Drive with Software and Electronic manuals PLC Specifications 8 DC inputs 12/24VDC 4 Input can be used as ANALOG 0-10VDC 4 Relay Outputs Operation 12/24VDC Stand alone plc controller Upload and Download from Laptop or PC Multiple time clocks, timers and counters, logic and functions • Built-in Real-Time Clock, Battery backup Package with: One controller ELC-12DC-DA-R-N Normal 0 false false false EN-US X-NONE X-NONE GENERAL SPECIFICATIONS Timers : 512 Counters : 512 Function Blocks : 512 Operation temp. : -20℃-55℃ Storage :-40℃-70℃ Protection : IP20(Non-waterproof) RTC accuracy : MAX ±2S/day RTC Backup at 25 °C : 20 days Program and settings Backup :10 years Data Power-off retentivity : 10 years Dimensions : 95*90*67 (Unit, mm) Certificate : CE Installation : 35mm-DIN rail or screw for installation Modify parameters via keypad LCD: yes Password protection : 4-digit number password protection or disable program upload function Communication interface : 1 Program/RS232 port ( TTL interface) Communication protocol : Modbus RTU/ASCII It’s optional for xLogic to be either slave or master in Modbus network. Technical Index Power supply: Nominal voltage DC 12-24V Operating limits DC 10.8-28.8V Immunity from micro power cuts Typ.5 ms Max. Startup current Max. 0.25A Max. absorbed power 3.5 W (10.8V dc) ; 4 W (28.8V dc) Protection against polarity inversions Yes Input parameters: Input No 8 ( I1-I8 ) Digital input 8 ( I1-I8 ) Analogue input 4 ( I1-I4)(0..10V DC) Digital inputs( I5-I8 ) Input voltage DC0-28.8V Input signal0 < 5V DC; 8 V DC;>1.7mA Input current 2.3mA @ 10.8V dc 2.6mA @ 12.0 V dc 5.2 mA @ 24 V dc 6.3 mA @ 28.8 V dc Response time 0 to 1 :<1 ms ;1 to 0 :<1 ms Maximum counting frequency 60k Hz(I7–I8) Sensor type Contact or 3-wire PNP Input type Resistive Isolation between power supply and inputs None Isolation between inputs None Inputs used as digital inputs( I1-I4 ) Input voltage DC0-28.8V Input signal0 < 5V DC; 8 V DC;>0.3mA Input current 0.4mA @ 10.8V dc 0.5mA @ 12.0 V dc 1.2mA @ 24 V dc 1.5mA @ 28.8 V dc Response time 0 to 1 :Typ. 1.5 ms ;1 to 0 :Typ. 1.5 ms Maximum counting frequency Typ.:4 HZ Sensor type Contact or 3-wire PNP Input type Resistive Isolation between power supply and inputs None Isolation between inputs None Inputs used as analog inputs( I1-I4 ) Measurement range DC 0—10V Input impedance Min, 24KΩ ; Max. 72KΩ Input voltage 28.8 V DC max Resolution 10bit ,0.01V Accuracy at 25 °C ± (Max.0.02)V Accuracy at 55 °C ± (Max.0.04)V Isolation between analog channel and power supply None Cable length 10 m max. shielded and twisted Output parameters: Output No. 4 (Q1-Q4) Output type Relay output Max. Allowable Power Force(Resistive) CE: 10A,250V AC/DC30V UL/CUL:10A,250V AC; 5A, DC28V Electrical durability Expectancy 105 Operations at Rated Resistive Load Mechanical life 107 Operations at No Load condition Response time Operate Time : 15 mSec. Max. Release Time : 10 mSec. Max. Built-in protections Against short-circuits: None Against overvoltages and overloads: None Switch frequency: Mechanism 10Hz Resistor/light load 2Hz Sensitive load 0.5Hz Other parameters: Ethernet port: Built-In(10M/100M) XlogicXlogic(by Ethernet) 1 xlogic works as server can connect 3 client xlogics. XlogicEtherne/Internet: xlogic works as TCP server or TCP client Weight Approx.300g
PLC Kit Programmable Controller Software 8 in, 4 Out, HMI, LAN, & USB interface
PLC Specifications. 1 USB Programming interface cable. 1 USB Flash Drive with Software and Electronic manuals. selecting from 70 integrated functions and linking up to 512 of them in the user program.
PLC Controller Hydroponic Grow System, Farm Automation 12 I/O 12V 24V
PLC Specifications. Immunity from micro power cuts. ※ T he ideal solution for simple automation tasks. selecting from 70 integrated functions and linking up to 512 of them in the user program. It’s optional for xLogic to be either slave or master in Modbus network.
